Implantation of an S-ICD in a patient with a DDD pacemaker and congenitally corrected transposition


Implantation of an S-ICD in a Patient with a DDD Pacemaker and Congenitally Corrected Transposition of the Great Arteries

In a new publication from Cardiovascular Innovations and Applications; DOI https://doi.org/10.15212/CVIA.2019.0597, Yu Zhang, Wen-Long Dai, Can-Can Lin, Qiao-Yuan Li and Cheng-Jun Guo from Beijing Anzhen Hospital, Capital Medical University, Beijing, China consider implantation of an S-ICD in a patient with a DDD pacemaker and congenitally corrected transposition of the great arteries.

Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy has become a viable alternative to conventional transvenous ICD implantation. Patients with congenitally corrected transposition of the great arteries (ccTGA) have a high risk of sudden cardiac death due to malignant arrhythmia. The interaction between the S-ICD system and the transvenous pacemaker system is not fully understood. The authors report a case of S-ICD implantation in a patient with ccTGA and a DDD pacemaker. The patient was a 30-year-old man with a previously placed pacemaker with diagnoses of congenital heart disease, ccTGA (SLL), left atrioventricular valve insufficiency, and third-degree atrioventricular block. He presented with an out-of-hospital cardiac arrest, and an S-ICD was implanted to prevent sudden cardiac death. Defibrillation checks were performed successfully. The authors tested the compatibility of the DDD pacemaker with the S-ICD and found that there was no interference between them. In conclusion, an S-ICD system is a reasonable and safe option in patients with ccTGA.

###

Citation information: Implantation of an S-ICD in a Patient with a DDD Pacemaker and Congenitally Corrected Transposition of the Great Arteries, Yu Zhang, Wen-Long Dai, Can-Can Lin, Qiao-Yuan Li and Cheng-Jun Guo, Cardiovasc. Innov. App., 2020, https://doi.org/10.15212/CVIA.2019.0597

Keywords: Subcutaneous implantable cardioverter-defibrillator; congenitally corrected transposition of the great arteries; pacemaker

CVIA is available on the IngentaConnect platform and at Cardiovascular Innovations and Applications. Submissions may be made using ScholarOne Manuscripts. There are no author submission or article processing fees. CVIA is indexed in the EMBASE, ESCI, OCLC, Primo Central (Ex Libris), Sherpa Romeo, NISC (National Information Services Corporation), DOAJ and Index Copernicus Databases. Follow CVIA on Twitter @CVIA_Journal; or Facebook.